Installation and Operation Manual Chapter 4 Configuration
Egate-100 Ver. 4.0 Services 4-7
Bridge
Port
Br
i
d
g
e
Port
Figure
4-4. Prioritized Ethernet Traffic
Table
4-4. Defining Priorities to Ethernet Traffic
Callout Step Menu Comments
1 Select a priority
classification method,
available under
Configuring
the Quality of Service
Configuration > Applications >
QoS > Queue Mapping Profile
> Priority Classification
The respective classification
method (802.1p, DSCP, IP
Precedence or None) affects
the number of priority
mapping tables.
2 Map the respective traffic
class to a priority, referred
to as tag value, available
under
Configuring QoS
Priority Mapping
Configuration > Applications >
QoS > Queue Mapping Profile
> Priority Mapping
This maps the traffic class to
a priority. The number of
available priorities are
determined by the
classification method:
IP Precedence: 0-7
802.1p: 0-7
DSCP: 0-63
3 Select the traffic class for
the traffic type, available
under
Configuring Unknown
Unicast, Multicast, and
Broadcast Priorities
Configuration > Applications >
QoS > Queue Mapping Profile
> Unknown Unicast Priority
> Multicast Priority
> Broadcast Priority
Unknown unicast, multicast
and broadcast traffic must be
mapped to separate traffic
queues (Traffic Class values).
Traffic Class: 0-3