Installation and Operation Manual Chapter 4 Configuration
Egate-100 Ver. 4.0 Configuring Egate-100 for Management 4-11
Table
4-7. Host Encapsulation Parameters
Parameter Description Possible Values
Host Tagging The Host Tagging mode:
Untagged: The host transmits and receives only untagged
frames. In VLAN-Aware mode, the host bridge port must be
set to Stripping.
Tagged: The host transmits VLAN-tagged frames and
receives only frames tagged with the same VLAN ID as that
of the host.
Default: Untagged
Untagged
Tagged
Host VLAN ID Sets the VLAN ID of the packets sent by the host. This
parameter only shows when Host Tagging is set to Tagged.
Default: 1
1-4094
Host Priority Tag Quality of Service priority tag for packets sent by the host. This
parameter only shows when Host Tagging is set to Tagged.
Default: 0
0–7
Configuring SNMPv3
Egate-100 supports SNMP version 3 entity, providing secure SNMP access to the
device by authenticating and encrypting packets transmitted over the network.
Configuring the SNMP Engine ID
Engine ID is an alphanumeric string used for identification of the Egate-100 agent
in the SNMPv3 environment. The engine ID must be unique to allow the user to
query the SNMP engine. It must be defined prior to enabling SNMPv3
functionality. The length of the string is up to 27 characters.
³ To define the SNMP engine ID:
1. Navigate to the SNMP Engine ID menu (Configuration > System >
Management > SNMP Engine ID),
2. Select Remaining Bytes and define the value of the engine ID section
reserved for user SNMP engine identification.
The value is automatically translated in hexadecimal format and displayed
in the read-only Engine ID field.