Installation and Operation Manual Chapter 6 Software Upgrade
ASMi-52 Ver. 2.8 Upgrading ASMi-52 Software via the File Utilities Menu 6-3
Figure
6-1. Downloading a Software Application File to ASMi-52 via TFTP
Use the following procedure to download software release 2.0 to ASMi-52 via the
File Utilities menu.
1. Verify that the ASMI52_2.8x.img file is stored on the PC with the TFTP server
application.
2. Verify that the ASMi-52 host has valid IP parameters.
3. Activate the TFTP server application.
4. Download the ASMI52_2.8x.img file from the PC to ASMi-52.
Configuration values shown in this chapter are examples only.
Verifying the ASMi-52 Host Parameters
The ASMi-52 host must have host IP parameters configured according to your
network requirements. Otherwise you will not be able to establish a proper
communication session with the TFTP server. Refer to the following manual
section for additional information:
Connecting to the ASCII Terminal
in Chapter 2
Working with Terminal
in Chapter 3
Configuring IP Host Parameters
and
Configuring the Host Encapsulation
in
Chapter 4.
³ To verify the ASMi-52 host parameters:
Display the Host IP menu (Configuration > System Configuration >
Management > Host IP), and verify that the host IP address, IP mask and
default gateway are configured according to your network requirements.