RADview FCD-IP User’s Manual Chapter 3 Port Management
Configuring Physical Parameters 3-19
Table 3-14. General Link Parameters (E1/T1 Ports) (Cont.)
Parameter Possible Values / Remarks
RAI The Remote Alarm Indication (for main links with sub links).
Off, On
For main links:
On transmits a yellow alarm indication on the E1 sub link when Link 1 is in yellow
alarm state .
For Sub links:
On transmits a yellow alarm indication on Link 1 when sub link E1 is in either yellow or
red alarm state.
Note: This field exists only when the E1/T1 has a sub link.
Inband Management The identifier of inband management over the link.
Off, Dedicated TS
TS Number TS being used as Dedicated TS
Only applicable when Inband Management=Dedicated TS.
Configuring E1/T1 Time Slot (TS) Assignments
RADview enables you to program the routing of time slots. A complete description
of the TS assignment function is discussed below.
To configure TS parameters:
1. Select a Link or Channel.
2. Select Configuration >Physical Parameters > TS Assign…
or
click the shortcut key on the toolbar
The TS Assignment dialog box appears.
Figure 3-13. TS Assignment