IPmux-11 Ver. 2.00 Overview 5-1
Chapter 5
Configuring IPmux-11 for a
Typical Application
This chapter provides detailed instructions for setting up a typical application using
two IPmux-11 units.
5.1 Overview
Application
The section provides detailed instructions for configuring two IPmux-11 units
operating opposite each other (see
Figure 5-1).
Figure 5-1. Two IPmux-11 Units Operating Opposite Each Other
Guidelines for Configuring IPmux-11 Units
There are four basic configuration steps (described below) that need to be
followed when deploying any IPmux unit.
1. IP Configuration – Setting the device host IP address and the manager IP address.
2. Physical layer configuration – Setting the TDM parameters (line type, clocking,
etc.) according to the application requirements and topology.
3. Creating bundles – Allocating timeslots to bundles
4. Connecting bundles – Directing the bundles defined above to remote IPmux
unit.