Installation and Operation Manual Chapter 4 Configuration
Optimux-34 Ver. 2.81 Performing Additional Tasks 4-25
Table
4-17. USER-ETH port status
Status Description
Enabled the USER-ETH port is open and enabled
Disable the USER-ETH port is disabled
Expired the license for this port has expired. New license is needed to enable this port
N day the number of days left for the present license to expire. This option is for
demo license
Verifying that the User Ethernet Port is Active
³ To verify that the User Ethernet port is active:
1. In the Utilities menu, select License Management.
The License Management menu appears:
Utilities>License Management
1. Feature Status
>
Please select item <1 to 1>
ESC-prev. menu; !-main menu; &-exit 1 user(s)
Figure
4-26. License Management Menu
2. Select Feature Status to display the status of the Ethernet User port.
The Feature Status screen appears:
Utilities>License Management>Feature Status
ETH Data Port ... (Enabled)
>
ESC-prev. menu; !-main menu; &-exit 1 user(s)
Figure
4-27. Feature Status Screen
The status of the Ethernet User port is explained in
Table
4-18
:
Table
4-18. ETH-USER Port Status
Status Description
Enabled The ETH-USER port is open and enabled
Disabled The ETH-USER port is disabled
Expired N day The number of days left for the present license to expire. This status
is for a demo license.