ASMi-52 Installation and Operation Manual Chapter 4 Managing ASMi-52 via a Terminal
Configuring ASMi-52 System Parameters 4-21
To access the Port Control menu:
Path: Main Menu > Configuration > Control Port > Port Control.
The Port Control menu appears (see Figure 4-24).
ASMi-52
Port Control
1. Port Control Mode > (Terminal)
2. Terminal >
3. Dial out >
4. Save
>
ESC-prev.menu; !-main menu; &-exit; @-scroll
Figure 4-24. Port Control Menu
Configuring Port Control Mode
CONTROL port of ASMi-52 operates in one of the following modes:
Terminal – direct connection to the control terminal (DCE mode) or to modem
(DTE mode)
Dial-out – connection to dial-out modem for alarm reporting
SLIP – connection to management station via Serial Line Internet Protocol.
Currently connection to ASMi-52 via SLIP is disabled.
To configure port control mode:
1. From the Port Control menu, select Port Control.
The Port Control Mode menu appears (see Figure 4-25).
ASMi-52
Port Control Mode (Terminal)
1. Terminal
2. Dial out
3. SLIP
>
ESC-prev.menu; !-main menu; &-exit; @-scroll
Figure 4-25. Port Control Mode Menu
2. From the Port Control Mode menu, select desired operation mode.
The Port Control menu appears.
3. From the Port Control menu, select Save to save the change.
Configuring User Name, Password, Pop-up Alarms and Security
Timeout
User name, password, pop-up alarms and security timeout are configured via
Terminal menu.
Note