Chapter 5 Cross Connection 5620 Model Descriptor for LA-110 User’s Manual
5-22 Configuring Cross Connections
Figure 5-12. FR VC Activate/Deactivate Connections
2. Fill in the fields, as described in Table 5-14.
3. Click <Save> to save the changes.
Table 5-14. Activate/Deactivate FR VC Connections Parameters
Parameter Valid Ranges/Remarks
ATM Endpoint
VPI The VPI value of the VC.
0…31
Read-only
VCI The VCI value of the VC.
0…255
Read-only
FR Endpoint
DLCI
16…991
Read-only
Connection
Operational
Status
Up, Down
Loopback Testing
To configure FR VC connection loopback testing:
1. In the Navigator, select the FR VC Connections container, right-click and
select Configure > Loopback Test.