RAD Data comm Megaplex-2100 Informations techniques Page 72

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 168
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 71
Chapter 1 Edit Configuration Mode RADview-PC/TDM Megaplex-2100/2104 User’s Manual
1-62 Port Level Configuration Operations
Parameter Possible Values / Remarks
OOS Signal State of the signaling bits when the link is in out-of-service (OOS) state:
Forced Idle – Signaling bits A and B are idle when the link is in out-of-service
state. In addition, if the line type is ESF, signaling bits C and D are also idle.
Forced Busy - Signaling bits A and B are busy when the link is in out-of-service
state. In addition, if the line type is ESF, signaling bits C and D are also busy.
Busy Idle - Signaling bits A and B are busy for 2.5 seconds, then become idle
until the out-of-service state ends. In addition, if the line type is ESF, signaling bits
C and D are idle for 2.5 seconds before switching to busy state.
Idle Busy - Signaling bits A and B are idle for 2.5 seconds, then become busy
until the out-of-service state ends. In addition, if the line type is ESF, signaling bits
C and D are busy for 2.5 seconds before switching to idle state.
Signaling Profile 1, 2, 3, 4, 5
IP Address IP Address
IP Mask IP Mask
Echo Canceller
Off
, On
To display bundle parameters for an ML-IP internal port:
1. In the Card View, click the required port.
2. From the Configuration menu, select Bundles...
The Bundles dialog box appears.
Vue de la page 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 167 168

Commentaires sur ces manuels

Pas de commentaire