User’s Manual Chapter 4 Configuring Typical Applications
Optimux-34 Ver. 2.81 Configuring Optimux-34 4-5
3. Click <Set> to implement the changes.
Table 4-2. System Dialog Box Parameters (Local/Remote)
Parameter Possible Values / Remarks
Type Indicates the Optimux-34 device type.
Read-Only
HW Version The hardware version number of the Optimux-34 device.
Read-Only
SW Version The software version number of Optimux-34 device.
Read-Only
Power Supply Main The operating status of the main power supply.
Active
Fault
None
Unknown
Read-Only
Power Supply Backup The operating status of the backup power supply.
Active
Fault
None
Unknown
Read-Only
Redundancy The availability of redundancy on the local/remote device.
Available
Not Available
Read-Only
Redundancy Mode The redundancy manner of operation:
Off
Auto
Manual
Read-Write
If the Redundancy Mode is set to ‘Manual’, you should manually request the
SNMP agent to configure the optSelectLink to ‘Main’ or ‘Back’ after the link has
switched from main to backup because when the Redundancy Mode is set to
‘Manual’ it means that there was a problem on the main that has been just fixed.
Note: This parameter is available only when the device has two links and
Redundancy is available.
Default Main Link Link A
Link B
Read-Write
Link Active Link A
Link B
Read-Only