Installation and Operation Manual Appendix D Command Language
FCD-E1 Front Panel Parameters D-7
Table D-3. Supervisory Configuration Parameters (Cont.)
Designation Function Values Configuration Guidelines
CALL ACT
Defines when the call-out
function is activated
A-CASE – Call-out is activated in any case.
L-FAILCall-out is activated only when a link
failure occurs or there is loc or remote sync loss.
Default: A-CASE
CAL TRG
Controls the use of the call-
out trigger
NONE – The call-out function is disabled
ALL – The FCD-E1 will initiate a call after each new
alarm
MAJOR – The FCD-E1 will initiate a call only when
a new major alarm condition is detected.
Default: NONE