System Installation
RADring
Installation & Operation Manual
3-14 Replacing The Ventilation Fan 3/11/98 12:29
3.12 Replacing The Ventilation Fan
Basic Module
1. Remove the four screws holding the power supply to the hub
enclosure. The screws are marked 1 through 4 in the illustration below.
12
34
Figure 3-3 Fan Screw Location in Basic Module
2. Disconnect the connector terminating the fan wires from the hub.
Connector
Fan
Figure 3-4 Fan Connector
3. Attach the new fan module in place of the old one.
4. Reattach the connector to the hub.
5. Secure the faceplate to the hub enclosure with screws 1 - 4.