Chapter 4 Troubleshooting and Diagnostics Installation and Operation Manual
4-4 Internal BERT ASM-40 Ver. 1.0
Local
DTE
Remote
DTE
Link
Interface
Link
Interface
Transmit
DIG
Pressed
Receive
Receive Transmit
Data
Data
Clock
Clock
Local ASM-40 Remote ASM-40
Figure 4-3. Local Digital Loopback
To activate the local digital loopback:
Press the DIG pushbutton on the local ASM-40 front panel.
The following LEDs are ON:
Local unit: TEST, RTS, and TD
Remote unit: DCD, RTS, TD and RD.
You can activate the local digital loopback by running remote digital loopback at
the remote unit. If the V54E section of the SW3 DIP switch is set to ON, the local
ASM-40 closes the DIG loopback when it detects the RLB activation at the remote
end.
4.2 Internal BERT
ASM-40 has a built-in BERT circuit consisting of a pattern generator and a pattern
tester. This circuit works in conjunction with the V.54 diagnostic loops and the
remote BERT to verify normal system operation and identify faulty equipment in
the event of the system failure.
The pattern transmitted by the BER system can be looped back for comparison
(modem self-test) or can be received by another ASM-40 (Two-BER test).
When used opposite another ASM-40, the complete link can be tested either
when the PATT button is pressed, or with external BERT transmitting the same
511-bit pattern.
Modem Self-Test
The test verifies that the modem is operating correctly (see
Figure 4-4
).
To activate the modem self-test:
1. Press the ANA pushbutton on the front panel. The TEST and DCD LEDs light
up.
Note