Front-Panel Operating Instructions
ASMi-450 Installation and Operation Manual 3-17
3.8 LCD Configuration Error Messages
The ASMi-450 detects configuration errors and displays a CONFIG
ERROR XY message. The code XY identifies the error. You will find below the
list of error messages and instructions that will help you correct the problem.
CONFIG ERROR 1
Illegal combination of loopbacks: you are trying to activate simultaneously
local and remote loopbacks. Only one loopback can be connected at a time.
CONFIG ERROR 2
You are trying to activate the REM REM loopback while synchronization is
lost.
CONFIG ERROR 3
You are trying to select the internal clock mode on the remote side.
CONFIG ERROR 4
You are trying to disconnect a loopback that is not active.
CONFIG ERROR 5
You are trying to change a parameter from the front panel when the password
is enabled.
CONFIG ERROR 6
You are trying to select a node number greater than 255.