Chapter 4 Configuration Installation and Operation Manual
4-12 Configuring for Operation Vmux-210 Ver. 1.1
Table 4-11. T1 Parameters (Cont.)
Parameter Description Possible Values/
Reference
Idle Code Idle Code of the T1 port 1..FF
Default: FF
Line Code Line Code of the T1 port B8ZS
AMI
Default: B8ZS
Rx Sensitivity Rx sensitivity of the T1 port
Note: This parameter is available only when
the Interface Type is defined as CSU.
LOW (-15 db)
HIGH (-36 db)
Default: LOW
(-15 db)
Tx Gain Level Tx gain level of the T1 port
Note: This parameter is available only when
the Interface Type is defined as CSU.
0 db
-7.5 db
-15 db
-22.5 db
Default: 0 db
Line Length Line length of the T1 port
Note: This parameter is available only when
the Interface Type is defined as DSU.
0-133
133-266
266-399
399-533
533-655
Default: 0-133
Fragmentation Maximum size (in bytes) of frames that are
not to be fragmented before mounting Serial
port; frames at are below this size are not
fragmented
200..1550
Default: 610
HDLC Mode Type of header added to HDLC frames Transparent HDLC
Cisco Bridged Eth
Default:
Transparent HDLC
Loop Detect Enables detection of loops in the TDM
network. When a loop is detected, a
corresponding alarm is recorded in the alarm
log, and all Ethernet frames being looped
back from the TDM uplink are blocked, and
prevented from being sent back to the
user's LAN. This mechanism prevents the
occurrence of undesired broadcast storms
and IP loops in the user’s LAN due to a loop
on the TDM network.
Enable
Disable
Default: Disable