RAD Data comm Vmux-210 Spécifications Page 142

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 192
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 141
Chapter 5 Configuring Vmux-210 for a Typical Application Installation and Operation Manual
5-6 Transferring Database to the Second Vmux-210 Vmux-210 Ver. 1.1
5.5 Transferring Database to the Second Vmux-210
To transfer the database to the second Vmux-210:
1. Upload the configuration file from the first Vmux-210 to the management
station via the TFTP protocol.
2. Download the configuration file to the second Vmux-210 via the TFTP
protocol.
See
Appendix B
for information on TFTP client/server operations for the
Vmux-210.
3. Establish a Telnet connection to the second Vmux-210 unit.
4. Display the Edit Bundle menu and set the Destination Bundle Number to 2.
5. Display the Ports Distribution menu, and configure the voice timeslots
belonging to the second Vmux-2100 bundle (Main Menu > Configuration >
Bundles > Channel Distribution > Configure):
Update from Time Slot – 1
To Time Slot – 15
Type – Voice
Bundle – 1
Destination Port ID – 2
Destination Time Slot ID – 1
Update Time Slot
Update from Time Slot – 16
To Time Slot – 30
Type – Voice
Bundle – 1
Destination Port ID – 2
Destination Time Slot ID – 17.
6. Update the second Vmux-210 database by typing @.
Now both remote Vmux-210 units are ready for operation.
The host IP and the default gateway values do not change when you download
the new configuration and update the database.
Note
Vue de la page 141
1 2 ... 137 138 139 140 141 142 143 144 145 146 147 ... 191 192

Commentaires sur ces manuels

Pas de commentaire