User's Manual Chapter 3 Configuration Management
RADview-SC/TDMoIP IPmux-11 Setting the Operational Parameters 3-15
Figure 3-13. T1 Interface Parameters Dialog Box
Table 3-8. E1/T1 Interface Parameters
Parameter Possible Values / Remarks
Port
E1, T1
Admin Status
Enable, Disable
Transmit Clock
Source
Source of the transmit clock
System: Recovered from the other interface network and used for data transmission on
this interface
Loopback: Transmit clock recovered from received data
Adaptive
: Adaptive clock regeneration
Rx Sensitivity Determines the maximum attenuation of the receive signal that can be compensated for
by the interface receive path.
Long Haul - -32 dB
Short Haul - -10 dB