Vue de la page 71
Appendix A Interface Specification Optimux-XLT1 Installation and Operation Manual
A-2 Ethernet and Fast Ethernet Connectors
A.2 Ethernet and Fast Ethernet Connectors
One Ethernet RJ-45 connector is mounted on each of the modules indicated in
Table A-2.
Table A-2. RJ-45 Connector Location
Module Use
Main Board Fixed Ethernet port at the front
ETH/10BaseT Modular Ethernet port in front slot B, C or D
FETH/10/100BaseT Modular Fast Ethernet port in front slot B, C or D
Management MNG-ETH at the back panel
The pin assignment of the Ethernet RJ-45 connector is depicted in Table A-3.
Table A-3. Ethernet RJ-45 Connector Pin Assignment
Pin Designation Function Direction
1 RX+ Receive - positive lead Input
2 RX- Receive - negative lead Input
3 TX+ Transmit - positive lead Output
6 TX- Transmit - negative lead Output
4, 5, 7, 8 Not connected
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com