MEGAPLEX-2100 I/O Modules
Multi-Channel Low-Speed Data Modules
LS-2 MTLS-2
LS-2A MTLS-2/2TS
LS-2A/2TS LS-2/M
Installation and Operation Manual
Notice
This manual contains information that is proprietary to RAD Data Communications. No part of this publication may
be reproduced in any form whatsoever without prior written approval by RAD Data Communications.
No representation or warranties for fitness for any purpose other than what is specifically mentioned in this manual is
made either by RAD Data Communications or its agents.
RAD Data Communications reserves the right to revise this publication and make changes without obligation to
notify any person of such revisions or changes.
For further information contact RAD Data Communications at the address below or contact your local distributor.
RAD data communications
Headquarters
12 Hanechoshet Street
Tel Aviv 69710 Israel
Tel: 972-3-6458181
Fax: 972-3-6498250
RAD data communications
US East
900 Corporate Drive
Mahwah, NJ 07430 USA
Tel: (201) 529-1100
Fax: (201) 529-5777
RAD data communications
US West
3631 South Harbor Boulevard
Suite 250
Santa Ana, CA 92704
Tel: (714) 850-0555
Fax: (714) 850-1555
© 1999 RAD Data Communications Publication No. 764-203-01/99
Vue de la page 0
1 2 3 4 5 6 ... 51 52

Résumé du contenu

Page 1

MEGAPLEX-2100 I/O ModulesMulti-Channel Low-Speed Data ModulesLS-2 MTLS-2LS-2A MTLS-2/2TSLS-2A/2TS LS-2/MInstallation and Operation ManualNoticeThis ma

Page 2

Introduction1-4 MP2100M-LS-2 Modules - Installation and Operation Manualchannels, a group of two /X.58 modules can provideup to twelve 4.8 kbps channe

Page 3 - Table of Contents

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-5/SDM modules can provide up to twenty 2.4 kbpschannels. Other combinations of

Page 4 - Appendix A. Connection Data

Introduction1-6 MP2100M-LS-2 Modules - Installation and Operation Manual• Transmission of five synchronous or asynchronous 9.6 kbps channels, inone m

Page 5 - List of Figures

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-7Channel CharacteristicsChannel Data RatesThe channels of all the LS-2 module v

Page 6 - List of Tables

Introduction1-8 MP2100M-LS-2 Modules - Installation and Operation Manual• For DTE interfaces, the lines are used as follows: The RTS line is an outp

Page 7 - Chapter 1

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-9Because of the use of synchronous-to-asynchronous conversion, whenconfiguring

Page 8 - Versions

Introduction1-10 MP2100M-LS-2 Modules - Installation and Operation ManualManagement andDiagnosticsChannel data rates, as well as all the operating par

Page 9

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-111.2 System Planning ConsiderationsThis section explains the multiplexing for

Page 10 - Introduction

Introduction1-12 MP2100M-LS-2 Modules - Installation and Operation Manual16 User DataBits2 3 4 5 6 7 8S Bit(Status Bit)F Bit(Framing andHousekeeping)E

Page 11

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-13Envelope No.7 8 10 11 12 13 14 15 16 17 18 19 2091 2 3 4 5 6 7 8 10 11 12 13

Page 13

Introduction1-14 MP2100M-LS-2 Modules - Installation and Operation ManualT - Housekeeping ByteS - Framing ByteLEGENDSubstructure No.122038567271706968

Page 14

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-15control bit, which indicates the information carried by each byte:0 Control d

Page 15

Introduction1-16 MP2100M-LS-2 Modules - Installation and Operation ManualTable 1-5. /SDM Version, Channel Availability for Highest User Rate of9.6 kb

Page 16

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-17Module GroupsTo allow the utilization of the maximal number of channels that

Page 17

Introduction1-18 MP2100M-LS-2 Modules - Installation and Operation Manual1.3 Technical SpecificationsModule Characteristics See Table 1-1Time Slots Us

Page 18 - 3.2 kbps 20 2.4 kbps

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-19Modem bit rates 2.4, 4.8, 9.6 or 19.2 kbps, synchronousModem clocking DTE1 (t

Page 19

Introduction1-20 MP2100M-LS-2 Modules - Installation and Operation Manual

Page 20

MP2100M-LS-2 Modules - Installation and Operation Manual 2-1Chapter 2.Module Installation andOperation2.1 GeneralThis chapter provides installation, c

Page 21

Module Installation and Operation2-2 MP2100M-LS-2 Modules - Installation and Operation Manual2.2 Preparation for InstallationThe operating mode of th

Page 22

Module Installation and OperationMP2100M-LS-2 Modules - Installation and Operation Manual 2-3DCE-DTESELECTORSDCEDCEDTEDTECH5CH4MODEDTEDTEMODEDCEDCEDTE

Page 23

MP2100M-LS-2 Modules - Installation and Operation Manual iTable of ContentsChapter 1. Introduction1.1 Functional Description ...

Page 24 - 1.3 Technical Specifications

Module Installation and Operation2-4 MP2100M-LS-2 Modules - Installation and Operation ManualSections 1, 2, 3 These sections select the channel transm

Page 25

Module Installation and OperationMP2100M-LS-2 Modules - Installation and Operation Manual 2-5CH6-10OFF-ASYNCON-SYNCCH1-5S1CH6-10ONOFFOFFLEN0ONOFF9BITL

Page 26

Module Installation and Operation2-6 MP2100M-LS-2 Modules - Installation and Operation Manual2.3 Module InstallationFor your safety, do not connect ca

Page 27 - Operation

Module Installation and OperationMP2100M-LS-2 Modules - Installation and Operation Manual 2-72.4 Module PanelsThe panels of the LS-2 modules are shown

Page 28

Module Installation and Operation2-8 MP2100M-LS-2 Modules - Installation and Operation Manualthe first group of channels (1 through 5) of the local mo

Page 29 - Figure 2-2. DIP Switch S1

Module Installation and OperationMP2100M-LS-2 Modules - Installation and Operation Manual 2-92.5 Normal IndicationsThe module starts operating as soon

Page 30

Module Installation and Operation2-10 MP2100M-LS-2 Modules - Installation and Operation Manual2.6 Configuration InstructionsGeneralThis section provid

Page 31 - 123 65478

Module Installation and OperationMP2100M-LS-2 Modules - Installation and Operation Manual 2-11Table 2-4. External Port ParametersParameter Description

Page 32 - 2.3 Module Installation

Module Installation and Operation2-12 MP2100M-LS-2 Modules - Installation and Operation Manual

Page 33 - 2.4 Module Panels

MP2100M-LS-2 Modules - Installation and Operation Manual 3-1Chapter 3.Alarms & Diagnostics3.1 GeneralThis chapter provides information on the alar

Page 34

ii MP2100M-LS-2 Modules - Installation and Operation ManualModules LS-2, LS-2A, LS-2A/2TS, MTLS-2...

Page 35 - 2.5 Normal Indications

Alarms & Diagnostics3-2 MP2100M-LS-2 Modules - Installation and Operation ManualTable 3-1. LS-2 Alarm Messages (Cont’d)Code Message Type Interpret

Page 36

Alarms & DiagnosticsMP2100M-LS-2 Modules - Installation and Operation Manual 3-33.3 DiagnosticsLoopback TypesThe LS-2 modules have an extensive se

Page 37

Alarms & Diagnostics3-4 MP2100M-LS-2 Modules - Installation and Operation ManualLocal Channel LoopbackThe local channel loopback is performed with

Page 38

Alarms & DiagnosticsMP2100M-LS-2 Modules - Installation and Operation Manual 3-5MTLS-2I/O MODULESMTLS-2I/O MODULESLocal UnitSystemManagementRemote

Page 39 - Alarms & Diagnostics

Alarms & Diagnostics3-6 MP2100M-LS-2 Modules - Installation and Operation ManualExternally InitiatedLocal ModemLoopback - LS-2/MOnlyThe external i

Page 40

Alarms & DiagnosticsMP2100M-LS-2 Modules - Installation and Operation Manual 3-7If the local subscriber receives its own signal when the local loo

Page 41 - 3.3 Diagnostics

Alarms & Diagnostics3-8 MP2100M-LS-2 Modules - Installation and Operation Manual

Page 42

MP2100M-LS-2 Modules - Installation and Operation Manual A-1Appendix A.Connection DataA.1 Interface Modules for MTLS-2/MTLS-2/2TSThe MTLS-2 and MTLS-

Page 43

Connection DataA-2 MP2100M-LS-2 Modules - Installation and Operation ManualThe interface modules have two 68-pin connectors, one for channels 1 throug

Page 44

Connection DataMP2100M-LS-2 Modules - Installation and Operation Manual A-3Table A-1. IM-S68/2 and IMB-S68/2 Modules, 68-Pin Connector Pin Assignment

Page 45

MP2100M-LS-2 Modules - Installation and Operation Manual iiiList of FiguresFigure 1-1. Typical Application for MTLS-2/X.50 Modules ...

Page 46

Connection DataA-4 MP2100M-LS-2 Modules - Installation and Operation ManualA.2 LS-2/M Module ConnectorsEach channel of the LS-2/M module has an RJ-11

Page 47 - Connection Data

Connection DataMP2100M-LS-2 Modules - Installation and Operation Manual A-5A.3 LS-2, LS-2A, and LS-2A/TS Modules ConnectorsThe LS-2, LS-2A and LS-2A/

Page 48

Connection DataA-6 MP2100M-LS-2 Modules - Installation and Operation ManualTable A-3. LS-2, LS-2A and LS-2A/TS Modules, 44-Pin Connector Pin Assignmen

Page 49

iv MP2100M-LS-2 Modules - Installation and Operation ManualList of TablesTable 1-1. Main Characteristics of LS-2 Module Versions ...

Page 50 - A.2 LS-2/M Module Connectors

MP2100M-LS-2 Modules - Installation and Operation Manual 1-1Chapter 1.Introduction1.1 Functional DescriptionGeneralThis manual describes the technical

Page 51

Introduction1-2 MP2100M-LS-2 Modules - Installation and Operation ManualLS-2 ModuleVersionsTable 1-1 lists the main characteristics of the various LS-

Page 52

IntroductionMP2100M-LS-2 Modules - Installation and Operation Manual 1-3Main FeaturesThis section describes the main features of the modules offered i