4 Rockwell Automation Publication 750-TD001H-EN-P - June 2013
PowerFlex 750-Series AC Drives
Catalog Number Explanation
a
Drive
Code Type Frames
20F PowerFlex 753 1…7
20G PowerFlex 755 1…10
21G PowerFlex 755 Drive with Options 8…10
1…3 4 5 6 7 8…10 11 12 13 14 15 16 17 18
20G 1 A N D 248 A A 0 N N N N N -LD-P3-P11
a b c d e f1…f4 g h i Cabinet Options (21G)
b
Future Use
d
Enclosure
Code Description Frames
R IP20, NEMA/UL Type Open, Frame 1 1
F § Flange (NEMA/UL Type 4X/12 back) 2…5
G IP54, NEMA/UL Type 12 2…7
N IP20/IP00, NEMA/UL Type Open 2…7
B Δ
IP20, NEMA/UL Type 1,
600 mm (23.6 in.) Deep,
Standard Cabinet
Color (RAL 7032)
8…10
J Δ
IP54, UL Type 12,
800 mm (31.5 in.) Deep,
Standard Cabinet
Color (RAL 7032)
8…10
K Δ
IP54, NEMA 12,
2500 MCC St
yle Cabinet & Options
w/MCC Power Bus, 800 mm (31.5 in.) Deep,
Standard Cabinet Color (RAL 7032)
8…10
L Δ
IP20, NEMA/UL Type 1,
800 mm (31.5 in.) Deep,
Standard Cabinet
Color (RAL 7032)
8…10
P Δ
IP20, NEMA/UL Type 1,
2500 MCC St
yle Cabinet & Options
w/MCC Power Bus, 800 mm (31.5 in.) Deep,
Standard Cabinet Color (RAL 7032)
8…10
W Δ
IP20, NEMA/UL Type 1,
2500 MCC St
yle Cabinet & Options
w/MCC Power Bus, 800 mm (31.5 in.) Deep,
CenterLine 2100 Gray (ASA49)
8…10
Y Δ
IP54, NEMA 12,
2500 MCC St
yle Cabinet & Options
w/MCC Power Bus, 800 mm (31.5 in.) Deep,
CenterLine 2100 Gray (ASA49)
8…10
T IP00, UL Open Type without Control POD 8…10
§ For Frames 6…7 a User Installed Flange Kit is available to convert a
Code N driv
e that provides a NEMA/UL Type 4X/12 back.
Frames 2…5 are IP20, Frames 6…7 are IP00.
Δ Available as a drive with options (21G).
e
Voltage Rating
Code Voltage
C 400V AC/540V DC
D 480V AC/650V DC
E 600V AC/810V DC
F 690V AC/932V DC (not UL listed)
f1
ND Rating
400V, 50 Hz Input
Code Amps kW
Frame
Enclosure Code
B, J,
L, T
FGN
K, P,
W, Y
R
2P1 2.1 0.75
222
1
3P5 3.5 1.5
5P0 5.0 2.2
8P7 8.7 4
011 11.5 5.5
015 15.4 7.5
022 22 11
030 30 15
333
037 37 18.5
043 43 22
060 60 30
4
4
4
072 72 37
5
085 85 45
55
104 104 55
6
140 140 75
§
6
170 170 90
205 205 110
260 260 132
7
302 302 160
7
367 367 200
456 456 250
460 460 250
8
–––
8 Δ
540 540 315
567 567 315
650 650 355
750 750 400
770 770 400
910 910 500
99Δ
1K0 1040 560
1K1 1090 630
1K2 1175 710
1K4 1465 800
1K5 1480 850
1K6 1590 900
10
10
Δ
2K1 2150 1250
§ For Frames 6…7 a User Installed Flange Kit is available to convert a
Code N driv
e that provides a NEMA/UL Type 4X/12 back.
Δ Available as a drive with options (21G).
f2
ND Rating
480V, 60 Hz Input
Code Amps Hp
Frame
Enclosure Code
B, J,
L, T
FGN
K, P,
W, Y
R
2P1 2.1 1
222
1
3P4 3.4 2
5P0 5.0 3
8P0 8.0 5
011 11 7.5
014 14 10
022 22 15
027 27 20
333
034 34 25
040 40 30
052 52 40
4
4
4
065 65 50
5
077 77 60
55
096 96 75
6
125 125 100
§
6
156 156 125
186 186 150
248 248 200
7
302 302 250
7
361 361 300
415 415 350
430 430 350
8
–––
8 Δ
485 485 400
545 545 450
617 617 500
710 710 600
740 740 650
800 800 700
99Δ
960 960 800
1K0 1045 900
1K2 1135 1000
1K3 1365 1100
1K4 1420 1250
1K5 1525 1350
10
10
Δ
2K0 2070 1750
§ For Frames 6…7 a User Installed Flange Kit is available to convert a
Code N driv
e that provides a NEMA/UL Type 4X/12 back.
Δ Available as a drive with options (21G).
c
Input Type
Code Description Frames
1
AC Input with Precharge, includes DC
Terminals
1…4,
8…10
AC Input without Precharge, includes DC
Terminals
5
4 DC Input with Precharge 5…10
A AC Input with Precharge, no DC Terminals
6…8
The DC Bus Bar kit (20-750-DCBB1-Fx) is available for Frames 6…7