Installation and Operation Manual Chapter 4 API Reference
MiRIC-E1, MiRIC-T1 Ver. 1.5 Parameters 4-7
Table 4-3. Configuration Parameters (Cont.)
Index R/W Description Default
0x708 R + W 0x5 =TAIS, transmit AIS
0 = Normal operation
1 = Transmits AIS.
Normal operation
Statistic Parameters
The statistics below are updated once a second, it is the host’s responsibility to poll
the statistics and to calculate the intervals.
Two bytes are reserved for each counter.
Table 4-4. Statistic Parameters
Index R/W Parameter Description E1/T1
0x640 R LCVCR 1 Line-Code Violation Count E1
0x641 R LCVCR 2 E1
0x642 R PCVCR 1 Path Code Violation Count E1
0x643 R PCVCR 2 E1
0x644 R FOSCR 1 Frames Out-of-Sync Count E1
0x645 R FOSCR 2 E1
0x646 R EBCR 1 E-Bit Counter E1
0x647 R EBCR 2 E1
0x672 R LCVCR 1 Line-Code Violation Count T1
0x673 R LCVCR 2 T1
0x674 R PCVCR 1 Path Code Violation Count T1
0x675 R PCVCR 2 T1
0x676 R FOSCR 1 Frames Out-of-Sync Count T1
0x677 R FOSCR 2 T1