RAD Data comm HCD-E1 Spécifications Page 100

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 232
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 99
Chapter 4 - Control from the Supervisory Port HCD-E1
Installation & Operation Manual
4-16 HCD-E1 Command Set Description 11/01/00 19:23
CLR TST
Purpose
Deactivate all the user-initiated tests and loopbacks being activated from this
unit.
Syntax
CLR TST
Use
To deactivate all the user-initiated tests and loopbacks, type:
CLR TST<CR>
HCD-E1 performs the command and displays the date and time , followed
by the HCD-E1 prompt. The TST LED goes off.
Note
If no test or loopback is currently activated, HCD-E1 displays ERROR 02 on
the terminal.
DATE
Purpose
Set the date for the HCD-E1 internal real-time clock.
Syntax
DATE
Use
1. Type:
DATE<CR>
HCD-E1 sends the entry line for the first parameter:
DAY = 01
2. If you do not want to change the current value of the parameter, press
<CR> to confirm it and continue to the next line, otherwise press F to
increase or B to decrease the displayed values, and then press <CR>
to confirm the selected value. HCD-E1 displays the entry line for the
next parameter.
3. Repeat the procedure in step 2 to set the month. HCD-E1 displays the
entry line for the year.
4. Type the four digits of the current year. HCD-E1 displays the entry line
for the week day.
5. Repeat the procedure in step 2 to set the week day, and then press
<CR> to end.
Vue de la page 99
1 2 ... 95 96 97 98 99 100 101 102 103 104 105 ... 231 232

Commentaires sur ces manuels

Pas de commentaire