RAD Data comm Vmux-2100 Manuel d'utilisateur Page 40

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 118
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 39
Chapter 3 Operation Vmux-2100 Installation and Operation Manual
3-4 Default Settings
Table 3-3. Vmux-2100 Default Settings (Cont.)
Parameter Default Value
Main Link (T1 Parameters)
Connect No
Clock Source Lbt
Frame Esf
Interface Type Dsu
Line Code B8ZS
Rx Sensitivity (CSU mode only) LOW (-30 dB)
Tx Gain Level (CSU mode only) 0 dBm
Line Length (DSU mode only) 0-133 ft
Restoration Time 1 second
Idle Code ff
Group
Ip Address 0.0.0.0
Bundle
Enter Bundle Number 1
Connect No
Function TDMoIP
Max Bytes In Multiplexed Frame 500
Destination IP 0.0.0.0
Destination Bundle 1
Packetizing Interval 30
Connectivity Packet Rate 60
Connectivity Timeout Cycles 3
TOS Parameters (Precedence) Routine
TOS Parameters (Delay) Normal
TOS Parameters (Throughput) Normal
TOS Parameters (Reliability) Normal Reliability
Coder/Rate G.723.1/6.4
Fax/Modem Enable
Fax/Modem (Rate) 4.8 kbps
MF Relay Disable
Minimum Pulse Width 30 msec
Minimum Power Level 0 dBm
VLAN Parameters (Vlan exists) No
VLAN Parameters (Vlan ID) 26
VLAN Parameters (Vlan Priority) 0
Vue de la page 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 117 118

Commentaires sur ces manuels

Pas de commentaire