Chapter 1 Introduction Installation and Operation Manual
1-8 Technical Specifications Optimux-106 Ver. 6.1
1.4 Technical Specifications
Uplink Interface
Number of Links
One or two (A and B)
Type
Optical
Applicable
Standards
ITU-T Rec. G.955
Performance
Refer to
Table
2-1
Connectors
ST, SC, or FC-PC, ordered option
(SF1/SF2 options only available with SC)
(SF3 option only available with SC/APC)
T1 Tributary
Interface
Applicable
Standards
ITU-T Rec. G.703, G.824
Nominal Line Data
Rate
1544 kbps
Line Code
B8ZS or AMI
Line Length (ft)
Five options for line length definition: 0-133, 134-266,
267-399, 400-533, 534-655 ft
Bit Rate Tolerance
±25 ppm
Line Impedance
100Ω (balanced)
Connectors
Balanced interface: RJ-45 connector
Transmit Level:
RJ-45
±3V (±10%)
User Ethernet
Port
Physical Interface
10/100BaseT
Transmission Mode
Full/half-duplex
Auto-negotiation enable/disable
Flow Control and Backpressure enable/disable