IPmux-8/16 User’s Manual Chapter 3 Configuration Management
Configuring IPmux-8/16 Ports at the Physical Layer 3-19
Table 3-9. Ethernet Interface Parameters (Cont.)
Parameter Possible Values / Remarks
Unconditional Tagging Controls port stacking operation and whether to add or remove a tag from the
frames on this port:
Unmodified – Tags are not modified
Tag - Add tag to untagged frames
Double Tag - Add tag to all frames
Untag - Remove a tag from the frame on this port
Note: Double Tag is not available for Network port
Stacking VID The PVID, the VLAN ID assigned to untagged frames or Priority-Tagged frames
received on this port:
1..4094
Default Priority Tag The default ingress User Priority for this port:
0..7
For User Port:
If Rate Limit = 32000: 2-7
If Rate Limit = 64000: 4-7
If Auto Negotiation is disabled (unchecked) and Max Capability Advertised is
different than the capabilities of the LAN (i.e. Max Capability=100Base-T full duplex
while the LAN works in 10Base-T half duplex), the NMS will disconnect.
Note