IPmux-1/1E Installation and Operation Manual Appendix E Parameters and Screens
Performance Monitoring E-29
E1 models
only
E.10 Performance Monitoring
E1/T1 Statistics
E1 STATISTICS
E1 over UTP
LOS: 0
LOF (Red): 0
LCV: 0
RAI (Yellow): 0
AIS: 0
FEBE: 0
BES: 0
DM: 0
ES: 0
SES: 0
UAS: 0
LOMF: 0
Time Since: sec 7------Valid Intervals 12----
1. Interval 0
ESC. Exit N. Next Inv:
Figure E-29. E1/T1 Statistics Menu
The following statistics are valid (and visible) for ESF and E1-CRC4 modes only:
BES, DM.
The following parameters are saved in the event log: LOS, LOF, Rcv.Yellow alarm,
Rcv. AIS and FEBE.
Compliance to Standards
E1: G.703, G.704, G.804, G.706, G.732, G.823
T1: ANSI T1.403, AT&T TR62411, G.703, G.704, G.804
The alarms and statistics are described in Table E-21.